Search

What are you looking for?

    Product Images Website CR80BW-min
    WebSite Product Images 1000x1000 CR80B-FCS
    Product Thumbnail 1000x1000 How DHU works
    Product Images Website CR80BW-min
    WebSite Product Images 1000x1000 CR80B-FCS
    Product Thumbnail 1000x1000 How DHU works
    Cotes Mobile Wind

    CR80B-FC/FCS

    Mobile adsorption dehumidifier for wind turbines 

    The CR80B-FC / CR80B-FCS is part of the Cotes Mobile Wind product family — portable adsorption dehumidifiers specifically adapted for onshore wind turbine applications.

    The unit is designed for retrofit installation inside wind turbine towers (WTG towers), where humidity, condensation, and airborne contamination present long-term operational risks.

    The CR80B-FC / FCS enables controlled dry-air supply without structural modification of the turbine and supports both targeted cabinet protection and general tower humidity stabilisation.

    Explanation of Naming

    The product designation follows established Cotes naming logic:

    • C – Cotes adsorption platform
    • R – Rotor-based adsorption technology
    • 80 – Capacity class
    • B – Building heritage (from the original Mobile range)
    • FC / FCS – Filter Cassette configuration

    FC = Filter Cassette
    FCS = Filter Cassette System (enhanced filtration configuration)

    Both variants share identical drying capacity and electrical characteristics. The difference lies in the filtration configuration, adapted to turbine environmental conditions.

    Position within the Cotes Mobile Wind family

    Cotes Mobile Wind units are developed for turbines that were not originally designed with integrated dehumidification.

    They enable:

    • Retrofit moisture protection
    • Flexible internal placement
    • Protection of electrical cabinets and control panels
    • Stabilisation of internal tower humidity

    The CR80B-FC / FCS represents the most compact unit within the Mobile Wind range and is typically used for:

    • Smaller tower volumes
    • Targeted protection strategies
    • Installations where space constraints apply

    Unlike offshore-engineered overpressure systems (CWO family), Mobile Wind units are flexible and redeployable.

    Read more + Read less -
    Wind-adapted filtration (FC / FCS):Filter cassette configuration designed for tower environments with dust and airborne contaminants.
    Adsorption rotor technology:Rotor-based moisture removal supporting humidity control during both operation and standstill periods.
    Compact retrofit solution:Designed for installation inside existing turbines without major structural modifications.
    Defined airflow performance:Dry air capacity 80 m³/h, regeneration air 40 m³/h, moisture removal 0.44 kg/h (at documented reference conditions).
    Portable deployment:Integrated handles support transport and positioning within the turbine tower.
    Moderate electrical demand:Connected load 0.83 kW, compatible with typical turbine auxiliary power availability.
    Request a quote

    TECHNICAL DATA

    Model DRY AIR (M3/H) REGENERATION AIR (M3/H) CONNECTED LOAD (kW) MOISTURE REMOVAL CAPACITY (KG/H) DIMENSIONS (WxDxH) DATASHEET PRODUCT MANUAL
    CR80B-FCS 80 40 0.83 0.44 485 / 313 / 327 Datasheet
    Request Manual
    CR100 100 40 1 0.6 373 / 284 / 520 Datasheet
    Request Manual
    CR240BW 240 40 1.05 0.8 400 / 333 / 361 Datasheet
    Request Manual
    CL26 Wind Turbines 350 /250 65 / 40 1.01 / 1.57 1.1 / 0.8 450 / 382 / 374 Datasheet
    Request Manual
    CR400BW 400 90 1.97 1.4 623 / 405 / 431 Datasheet
    Request Manual
    check

    PORTABLE OPERATION 

    Designed for retrofit installation and flexible placement inside wind turbine towers, with integrated handles supporting safe manual transport and repositioning. 

    check
    APPLICATION KNOW-HOW

    Developed specifically for onshore wind turbines where humidity control was not originally integrated, supporting both targeted cabinet protection and general tower climate stabilisation. 

    check
    ADSORPTION DRYING PRINCIPLE 

    Rotor-based adsorption dehumidification for reliable moisture removal across varying temperature conditions, including low-temperature and standstill scenarios where condensation risk increases. 

    check
    MOBILE WIND FAMILY DESIGN

     Built on the Cotes Mobile concept and adapted for wind turbine environments, featuring defined configurations and wind-adapted filtration rather than permanent integrated overpressure systems. 

    Frequently Asked Questions

    For our full FAQ section you can go to www.cotes.com/FAQ 

    On this page we highlight some of the more frequently asked questions from customers.

     

    What is the CR80B-FC / FCS used for in wind turbines?
    open close

     The unit is typically used to supply dry air inside the WTG tower, reducing condensation risk and protecting electrical cabinets and control systems. 

    Both variants share the same drying performance.
    The difference lies in the filtration configuration:

    • FC provides wind-adapted filter cassette protection.
    • FCS includes an enhanced filter cassette system for environments with higher contamination levels.

     The CR80B-FC / FCS is primarily positioned for onshore wind retrofit applications. Offshore installations typically require engineered overpressure systems such as the Cotes Wind Overpressure (CWO) family that creates an overpressure while filtrating salt from the air.

    During standstill, ventilation is reduced and condensation can form on internal surfaces with temperature fluctuations. Moisture combined with salt or contaminants increases corrosion risk and may reduce electrical insulation resistance during restart. Controlled humidity reduces this risk.